LG Refrigerators2023–present

Error Code E IF

Icing Fan Motor Error — BLDC Fan Motor for Ice Making

Moderate

Address soon - your appliance may not work properly

What This Means

No feedback signal from icing fan motor for more than 65 seconds; Defective BLDC motor, drive IC, or transistor; Loose connection to icing fan motor

How to Fix

  1. 1

    Step 1: Reset unit and enter Test Mode 1 (press test button 1 time).

  2. 2

    Step 2: Measure fan motor supply voltage at CON4 pins 12-11 — expected 11.4 to 12.6V; if absent, replace Main PCB.

  3. 3

    Step 3: Open freezer door and check airflow — if windy, proceed to Step 4.

  4. 4

    Step 4: Rotate fan motor blade by hand — if sticky, replace fan motor.

  5. 5

    Step 5: Measure fan feedback voltage at CON4 pins 10-11 — expected NOT 0 or 5V; if 0 or 5V, replace fan motor.

  6. 6

    Step 6: Measure fan PWM voltage at CON4 pins 9-11 — expected NOT 0 or 5V; if 0 or 5V, replace Main PCB.

  7. 7

    Step 7: If all checks are normal, explain to customer.

This Error Applies To

LG LRFOC2606 Series Refrigerators (2023) (2023–present)

Service manual exact match: LRFOC2606VService manual exact match: LRFOC2606DService manual exact match: LRFOC2606S